Skip to content

BriefingA decision framework, not a measurement

After the EV: heat pumps, home batteries and solar inverters as flexible load

The EV comes first because it is the easiest flexible load a household has. Each device after it is worth adding for a different reason, and the value case from the car does not carry over.

Peter Hofierka

Co-founder and CTO, Wattiva

6 min read

Last reviewed

  • Flexibility lead

Key takeaways

  1. The EV comes first because it combines a large battery, long parking, a deadline hours away and cloud control that already exists. No other household device has all four.
  2. Heat pumps shift for minutes to hours and draw most on cold evenings. In 2026, January and February had the narrowest daily spreads of the ten complete months, so their case rests on evening shape and peak avoidance, not a night-long spread.
  3. Home batteries are two-way and always at home, but their value to the retailer is only what price-aware control adds over the owner's own self-consumption strategy.
  4. Curtailing solar export in negative hours helps the retailer only if the retailer carries the exported energy. Otherwise it does nothing for the retailer and may cost the customer.

Every device after the car is harder to make flexible: smaller, shorter, or tied to comfort or the customer's own solar. Each is worth adding for its own reason. On status: EV smart charging and solar energy sharing are live on our platform today; other device types are added per project. This is how we assess them, not a list of what runs.

Why the EV comes first

  • A large battery. A car battery typically stores several times what a home battery does, and a typical session needs hours of charging, not minutes.
  • Parked most of the day. A car is stationary most hours.
  • A deadline hours away. "80% by 7:00" leaves many hours, and the customer cares about the end state, not the path.
  • Cloud control already present. Many cars and connected chargers already expose remote control through the manufacturer's cloud, so nothing is installed at home.

Together, these let the car be scheduled with little effect on the customer (the EV playbook covers its value). For each device below: what can be shifted, what the customer agrees to, what makes control hard, and how value differs.

Heat pumps: short shifts at the worst time

A heat pump shifts load for minutes to a few hours, not overnight, and it draws most on cold evenings, when the system peak comes too.

  • What can be shifted. Heating or hot water can be brought forward or delayed while thermal mass, or the tank, holds temperature inside the comfort band. Hot water usually shifts further. How far depends on insulation, outside temperature and the band; in a poorly insulated house on a cold night, very little.
  • What the customer agrees to. A comfort band and hours when the system is not touched. Unlike a car's end state, comfort is felt continuously; a breach is noticed within the hour.
  • What makes control hard. Interfaces vary by manufacturer and model; many expose only coarse modes, not a setpoint. The unit's controller can undo a command. Pre-heating raises losses.
  • How the value differs. The shift is short, so value lies in leaving the dearest evening hour or two, not in a night-long spread. And it arrives in the heating season: in 2026, January and February had the narrowest daily spreads of the ten complete months.
Average daily TB4 per MWh by month, 2026 (€/MWh)
MonthSlovakiaCzechiaPolandGermany–Luxembourg
January96.179.2112.162.2
February63.057.767.852.1
March142.4129.4144.2130.9
April145.5147.9156.5152.0
May154.8153.0142.8152.4
June189.0156.4161.6171.6
July145.9137.4141.9147.0
August158.2142.8179.8155.7
September192.8175.2183.8183.3
October161.4128.9165.3128.0
Complete months only. November 2026 is partial and not shown. Source: ENTSO-E Transparency Platform, read 12 November 2026.

MethodHow to read the table

Daily TB4 = sum of the four dearest hourly day-ahead prices minus sum of the four cheapest. Monthly figure = month's TB4 ÷ (4 × days). It measures a four-hour shift to any hour, which a heat pump cannot make: read it as each month's price shape, not heat-pump value. In all four zones January and February were the two lowest of the ten complete months.

That does not make the heat pump worthless. Its load is largest in those months, and moving it off a cold evening's peak matters to balancing as well as procurement. But build its case on evening hours, not daily spreads.

Home batteries: small, two-way and already busy

  • What can be shifted. Energy both ways, any hour. A home battery holds a fraction of a car's energy, but it is always at home and its owner rarely notices how it is used.
  • What the customer agrees to. A reserve kept for the household, and whether the retailer may charge from and discharge to the grid, not only shift the household's own solar.
  • What makes control hard. Most sit beside solar and run self-consumption: charge from midday surplus, discharge in the evening. Retailer control competes with that. Cycles add wear, and warranties may limit cycling or grid charging. Export and metering rules differ by market, so a discharge to the grid may settle differently from an avoided import.
  • How the value differs. Two-way capacity both buys low and avoids buying high, so each kWh of capacity works harder than one-way shifting. But the energy is small and largely used for self-consumption already. The retailer's value is what price-aware control adds over the battery's own strategy, not its full cycle.

Solar inverters: curtailment, and who owns the surplus

Solar output cannot be shifted, only reduced. The controllable action is to cut export, or output, when the price is negative. Whether that helps the retailer depends on who carries the exported energy.

  • What the customer agrees to. That export may be reduced in specific hours, and on what terms if they are paid for export.
  • What makes control hard. Cutting export while still supplying the house from the panels needs an inverter that supports export limiting, with a meter at the connection point. Not every inverter or installation has both.
  • How the value differs. If the retailer buys the household's export at a fixed price and has it in its balancing group, every MWh exported in a negative hour costs the fixed price plus the cost of disposing of it below zero. Curtailment avoids both. If the export is settled with another party or netted on the customer's bill, curtailment does nothing for the retailer, and it may cost the customer the credit for those kWh.

How often it matters depends on the market. From 1 January to 11 November 2026, Slovakia had 265 hours with a negative hourly day-ahead price out of 7,560, Germany–Luxembourg 474 and the Netherlands 405. In Slovakia the hours are concentrated in spring: April, May and June held 90 + 61 + 48 = 199 of the 265.

Hours with a negative day-ahead price, by bidding zone, hours

Hours with a negative day-ahead price, by bidding zone (hours)
Category202420252026, to 11 Nov
Slovakia288 hours299 hours265 hours
Czechia315 hours322 hours278 hours
Poland197 hours311 hours317 hours
Hungary262 hours281 hours239 hours
Austria296 hours378 hours260 hours
Germany–Lux.457 hours576 hours474 hours
Netherlands458 hours584 hours405 hours

Hours whose hourly-average day-ahead price was strictly below zero; hours at exactly zero are not counted. 2026 covers 7,560 hours, against 8,784 in 2024 and 8,760 in 2025. Source: ENTSO-E Transparency Platform.

Curtailment is the blunt tool. Better to move load into a negative hour: the car, the battery, the hot-water tank. That is where device classes meet, and where energy sharing matches local solar to neighbours.

What changes for the product

A new device class changes the product more than the engine. Scheduling energy against prices inside customer limits generalises. The customer promise, the control interface and the settlement baseline do not, so each device needs its own onboarding, reward logic and compliance measure.

Household devices as flexible load, compared
EVHeat pumpHome batterySolar inverter
DirectionLoad, one wayLoad, one wayTwo wayGeneration, down only
Shift windowHours, to a deadlineMinutes to a few hoursHours, limited by capacityNone; curtail only
Customer promiseA target by a timeA comfort bandA reserve keptExport terms
Main control riskNot plugged in, overridesComfort, coarse controlsConflict with self-consumption, wearExport limiting support; who owns the surplus
Status on our platformLiveAdded per projectAdded per projectAdded per project
Live today on our platform: EV smart charging and solar energy sharing. Further device types are added per project.

That is why we add device types per project, against a named retailer's customer base and market rules, rather than claim a catalogue. If your customers' next device is a heat pump, the right first step is a short list of the models they own and how those models expose control.

Sources

  1. 1.ENTSO-E Transparency Platform, day-ahead prices (SDAC) — read 12 November 2026; data through market day 11 November 2026

Next step

Start from your customers' devices

Tell us which devices your customers own and in which market. We will say what can be controlled, what the customer would agree to, and what we would add in a project.

Written by

Peter Hofierka

Co-founder and CTO, Wattiva

About Wattiva Energy Intelligence

Wattiva Energy Intelligence is our research series on demand-side flexibility at household level. It is built on public market data, with the method shown, and on what we learn operating our own portfolio in Slovakia.

Savings discussed in this series concern the commodity price. Network fees still apply.

All research